AC Combiners & Recombiners

UL listed
(480 - 600VAC) 400 - 4000A

400 - 1000A

AC Combiners (480 - 600VAC)

(UL 891 Construction, UL 508A cert.), (MLO) Wall mount platform for 480 – 600VAC PV applications. Supporting up to (8) feeders. Multiple feeder breaker size options & combinations available, with bus ampacity sized at 1000A. MVT connection via cable. Thermally engineered NEMA 3R enclosure. 

  • Combines 2 – 8 string inverters
  • 480 – 600VAC 3PH, 3W / 4W
  • 400A – 800A bus rating, MLO
  • 40 – 250A MCCB’s TM / ETU trip,
    80% / 100%
  • Interrupt rating up to
    50kAIC @ 600VAC, 50kAIC @480VAC
  • Incoming cable size to 350MCM
  • Outgoing cable size 350 – 750MCM (2) cables per phase

400 - 1000A
Wall Mounted

AC Combiners (480 - 600VAC)

(UL 891 construction, UL 508A cert.), (MCB) or (MLO) wall mount platform for 480 – 600VAC PV applications. Supporting up to (10) feeders. Multiple feeder breaker size options & combinations available, with bus ampacity sized at 1500A. MVT connection via cable. Thermally engineered NEMA 3R enclosure.

  • Wall Mounted (60″ X 36″ X 18″)
  • 400 – 1000A Main / MLO
  • 100% Rated Main % Feeder (Option
  • Main Breaker LI / LSIG, LSIG W AERMS
  • Feeder Ranges: 100, 150, 250AF
  • Electronic Trip Main / Feeders
  • Interrupt Ratings:
    50kAIC @ 480VAC, 50kAIC @ 600VAC
  • Surge Suppressor Option
  • Bottom Entry / Exit
  • Optional Output CT’s

400 - 1200A Freestanding

AC Combiners (480 - 600VAC)

(UL 891 listed) (MCB) or (MLO) free standing platform for 480 – 600VAC PV applications. Supporting up to (14) feeders. Multiple feeder breaker size options & combinations available, with bus ampacity sized at 1500A. MVT connection via cable. Thermally engineered NEMA 3R enclosure.

  • Freestanding (80″ X 42″ X 24″)
  • 400 – 1200A Main / MLO
  • 100% Rated Main % Feeder (Option)
  • Main Breaker LI / LSIG, LSIG W AERMS
  • Feeder Ranges: 100, 150, 250, 400, 600AF
  • Electronic Trip Main / Feeders
  • Interrupt Ratings:
    65kAIC @ 480VAC,
    50kAIC @ 600VAC
  • Surge Suppressor Option
  • Bottom / Top / Side Entry Option
  • Optional Output CT’s

1200- 4000A

AC Combiners (480 - 600VAC)

(UL 891 listed) (MCB) or (MLO) switchboard platform for 480 – 600VAC PV applications. Supporting up to (40) feeders in one switchboard. Multiple feeder breaker size options & combination are available, with bus ampacities from 1200 – 4000A. MVT connections available by direct bus or by cable. Thermally engineered NEMA 3R enclosure.

  • 3PH, 4W (90″ x 60″ x 36″)
  • 1200 – 4000A main breaker / bus rating options
  • Drives up to 3,500kVA transformer @ 600VAC
  • (MLO) option also available
  • High density (up to 40 x 100AF) branch feeders
  • Feeder ranges: 125, 150, 250, 400, 600, 800, 1000AF
  • Interrupt Ratings: *Up To* 100kAIC @ 480VAC, 65kAIC @ 600VAC
  • Surge suppressor option
  • Oversized lug options for feeders available
  • CT / PT / metering packages available