AC Combiners & Recombiners
UL Listed
(660 - 800VAC) 300 - 3000A
400A
Disconnect
AC Non-Fused Disconnect.
(660 - 800VAC)
(UL 508A Listed) Local AC inverter disconnect for 660-800VAC inverters. Non-fused disconnect. Thermally engineered NEMA 3R enclosure
- 660 – 800VAC, 400A Local
- 34″ X 17″ X 14″ Deep NEMA 3R Rackmount
- *Up To* 600MCM / 1 Cable / Phase
- *Up To* 350MCM / 2 Cable / Phase
300A MCCB Disconnect
AC Disconnect.
(660 - 800VAC)
(UL 508A Listed) Local AC inverter disconnect for 660-800VAC inverters. Non-fused disconnect. Thermally engineered NEMA 3R enclosure
- 660 – 800VAC, 120 – 300A Circuit Breaker Disconnect
- 34″ X 17″ X 14″ Deep NEMA 3R Rackmount
- *Up To* 500MCM, 1 Cable / Phase
- *Up To* 250MCM, 2 Cables / Phase
- Electronic Trip MCCB, 35kAIC @ 800VAC
400 - 1000A
Rack Mount
AC Combiner (660 - 800VAC)
(UL 891 construction, UL 508A Cert.), (MLO) wall mount platform for 660- 800VAC PV applications. Supporting up to (4) feeders. Utilizes ABB T5X MCCB (adjustable from 120-300A. Bus ampacity up to 1000A. MVT connection via cable. Thermally engineered NEMA 3R enclosure.
- Combines 2 – 4 inverters
- Up To 4 MCCB’s 400AF / 120
- 100% Rated, Electronic Trip
- Incoming (From Inverter) Up To 500MCM 1/Phase
- Outgoing Up To 750MCM , Up To 3/Phase
- Interrupt Rating 35kAIC
- Options: Fans, Heater, CT’s
1200 - 3000A
(FS) (MLO)
AC Combiner (660 - 800VAC)
(UL 891 Listed), (MLO) freestanding SWBD 660 – 800VAC PV applications. Supporting up to (14) feeders. Feeders utilize ABB T5X MCCB (trip selectable from 120 – 300A), with bus ampacity sized at 1200 – 3000A. MVT connection via cable or direct bus. Optional SEL 751A for secondary overcurrent protection (LSIG). Thermally engineered NEMA 3R enclosure.
- 800VAC, 3PH, 3W/4W, 90″ X 60″ X 32″
- 3000A Bus, MLO, *Up To* 3000kVA Transformer
- Up To (14) MCCB’s *Up To* 300A Ea. (100% Rated), TM *Or* ETU Trip, Adjustable From 120A To 300A
- Cable *Or* Direct Bus Connection To MVT
- UL Listed Main Protective Relay (751A), (LSIG, AERMS)
- CT / PT / Revenue Grade Metering Option
- Surge Suppressor Option
- Thermal Management Options
1200 - 3000A
(FS) (MCB)
AC Combiner (660 - 800VAC)
(UL 891 Listed), (MCB) or (MLO) freestanding SWBD 660 – 800VAC PV applications. Supporting up to (20) feeders. Main breaker 1200 – 3000A, LSIG, AERMS. Feeders utilize ABB T5X MCCB (trip selectable from 120 – 300A). MVT connection via cable or direct bus. Thermally engineered NEMA 3R enclosure.
- 800VAC, 3PH, 4W, 90″ X 60″ X 36″
- 1200 – 3000A Bus, (MCB) Or (MLO), Up To 3000kVA Transformer
- Interrupting Rating Of 35kALIC @ 800VAC
- Cable *Or* Direct Bus Connection To MVT
- UL Listed MCB (LSIG, AERMS)
- CT / PT / Revenue Grade Metering Option
- LSIG (SEL 751A) Optional For (MLO)
- Surge Suppressor Option
- Thermal Management Options